Ireland Vivid Shower Valve / Handset Flow Rates
All flow rates are expressed in Litres per minute at 38 deg mixed water temperature.
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV021 | 0.5 | 8.3 | 4.7 | 6.8 |
| 1 | 13.1 | 7.7 | 12.8 | |
| 2 | 19.8 | 11.4 | 19.8 | |
| 3 | 25.4 | 14.2 | 24.7 | |
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV009 | 0.5v | 4.6v | 3.9v | 4.9v |
| 1^ | 6.8^ | 5.5^ | 7^ | |
| 2^ | 10.1^ | 8.2^ | 10^ | |
| 3^ | 12.3^ | 10.2^ | 12^ | |
v = Test performed with LP Head
^ = Test performed with HP Head
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV022 | 0.5 | 11.2 | 5.7 | 11.7 |
| 1 | 17.9 | 8.8 | 17.3 | |
| 2 | 25.8 | 12.5 | 25.2 | |
| 3 | 32 | 15.3 | 30.6 | |
| Component | Bar |
|---|---|
| SV023 | 0.5 |
| 1 | |
| 2 | |
| 3 | |
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV010 | 0.5 | 12 | 5.8 | 10.4 |
| 1 | 18.7 | 8.5 | 16.7 | |
| 2 | 27.5 | 12.6 | 24 | |
| 3 | 31 | 16.2 | 29.4 | |
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV008 | 0.5 | 5.2 | 3.9 | 4.1 |
| 1 | 7.9 | 6.1 | 8.2 | |
| 2 | 12.2 | 9.5 | 12.4 | |
| 3 | 15.3 | 11.5 | 15.8 | |
| Component | Bar | Bar Valve |
|---|---|---|
| SV011 | 1 | 7.4 |
| 2 | 11.2 | |
| 3 | 13.8 | |
| Component | Bar | 2 Port Valve | 2 Port with Diverter | 3 Port Valve |
|---|---|---|---|---|
| SV014 | 0.5 | 10.4 | 5.3 | 9.1 |
| (each body jet) | 1 | 13.1 | 8.2 | 14.2 |
| 2 | 22.2 | 12.4 | 21 | |
| 3 | 28 | 15.1 | 25.4 | |